{"id":143,"date":"2026-09-22T15:32:42","date_gmt":"2026-09-22T12:32:42","guid":{"rendered":"https:\/\/daimmed.com.tr\/?page_id=143"},"modified":"2026-09-22T15:35:26","modified_gmt":"2026-09-22T12:35:26","slug":"magictouch-pta","status":"publish","type":"page","link":"https:\/\/daimmed.com.tr\/en\/magictouch-pta\/","title":{"rendered":"MagicTouch PTA"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"143\" class=\"elementor elementor-143\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f1fd93a e-grid e-con-boxed e-con e-parent\" data-id=\"f1fd93a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-0b5d6b2 e-con-full e-flex e-con e-child\" data-id=\"0b5d6b2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-80840fb elementor-widget elementor-widget-text-editor\" data-id=\"80840fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h1><strong>MagicTouch\u2122 PTA<\/strong><\/h1><h3><strong>Sirolimus-Coated Peripheral Angioplasty Balloon<\/strong><\/h3><p>MagicTouch\u2122 PTA is a sirolimus-coated PTA balloon catheter developed for the endovascular treatment of peripheral artery diseases.<\/p><blockquote><p>The product is designed for the treatment of de novo lesions, stenotic lesions and intra-stent restenoses observed in superficial femoral artery (SFA), popliteal artery, sub-knee arteries (BTC) and iliac arteries by percutaneous transluminal angioplasty method.<\/p><p>The sirolimus-based drug delivery technology aims to help reduce the risk of restenosis and preserve vessel patency.<\/p><\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f8e81f4 e-con-full e-flex e-con e-child\" data-id=\"f8e81f4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-07dbaf5 elementor-widget elementor-widget-image\" data-id=\"07dbaf5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"555\" height=\"177\" src=\"https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA.jpg\" class=\"attachment-full size-full wp-image-146\" alt=\"\" srcset=\"https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA.jpg 555w, https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-300x96.jpg 300w, https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-520x166.jpg 520w\" sizes=\"(max-width: 555px) 100vw, 555px\" data-id=\"146\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24414d9 elementor-widget elementor-widget-image\" data-id=\"24414d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"2048\" height=\"1194\" src=\"https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-Sirolimus-Coated-Balloon-for-Peripheral-artery-disease-1-2048x1194-1.webp\" class=\"attachment-full size-full wp-image-147\" alt=\"\" srcset=\"https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-Sirolimus-Coated-Balloon-for-Peripheral-artery-disease-1-2048x1194-1.webp 2048w, https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-Sirolimus-Coated-Balloon-for-Peripheral-artery-disease-1-2048x1194-1-300x175.webp 300w, https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-Sirolimus-Coated-Balloon-for-Peripheral-artery-disease-1-2048x1194-1-1024x597.webp 1024w, https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-Sirolimus-Coated-Balloon-for-Peripheral-artery-disease-1-2048x1194-1-768x448.webp 768w, https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-Sirolimus-Coated-Balloon-for-Peripheral-artery-disease-1-2048x1194-1-1536x896.webp 1536w, https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-Sirolimus-Coated-Balloon-for-Peripheral-artery-disease-1-2048x1194-1-515x300.webp 515w, https:\/\/daimmed.com.tr\/wp-content\/uploads\/2026\/09\/MagicTouch-PTA-Sirolimus-Coated-Balloon-for-Peripheral-artery-disease-1-2048x1194-1-650x379.webp 650w\" sizes=\"(max-width: 2048px) 100vw, 2048px\" data-id=\"147\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-92b0797 e-grid e-con-boxed e-con e-parent\" data-id=\"92b0797\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-67a31d4 e-con-full e-flex e-con e-child\" data-id=\"67a31d4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-22616e6 elementor-widget elementor-widget-text-editor\" data-id=\"22616e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h3><strong>Main Areas of Use<\/strong><\/h3><ul><li>De novo peripheral artery lesions.<\/li><li>Stenotic lesions<\/li><li>Intra-stent restenosis<\/li><li>Superficial femoral artery lesions.<\/li><li>Lesions of the popliteal artery<\/li><li>Arterial lesions below the knee<\/li><li>Iliac artery lesions<\/li><li>Chronic limb-threatening ischemia (CLTI)<\/li><\/ul><h3><strong>Nanolute\u2122 Drug Delivery Technology<\/strong><\/h3><p>MagicTouch\u2122 PTA features Nanolute\u2122 technology, developed to ensure effective and controlled delivery of sirolimus to the targeted vascular tissue.<\/p><p>Sirolimus is formulated into submicron particles within biocompatible phospholipid carriers. The special coating applied circumferentially to the balloon surface helps distribute the drug homogeneously throughout the targeted lesion.<\/p><p>The coating process carried out under low pressure ensures that the entire balloon surface is coated. When the balloon is inflated, the aim is to transfer sirolimus evenly to the vessel wall.<\/p><h3><strong>Featured Features<\/strong><\/h3><ul><li>Sirolimus-coated peripheral angioplasty balloon.<\/li><li>Wide range of applications for peripheral artery diseases.<\/li><li>Nanolute\u2122 submicron drug delivery technology<\/li><li>Peripheral coating that covers the entire balloon surface.<\/li><li>Homogeneous and controlled drug distribution.<\/li><li>Biocompatible phospholipid drug carrier.<\/li><li>Three or six-story balloon structure.<\/li><li>Semi-compatible balloon design.<\/li><li>Wired (OTW) catheter system.<\/li><li>Wide range of diameter and length options suitable for different vessel anatomies.<\/li><li>A treatment approach that leaves no permanent implant inside the vein.<\/li><\/ul><h3><strong>Technical Specifications<\/strong><\/h3><table><tbody><tr><td><p><strong>Feature<\/strong><\/p><\/td><td><p><strong>Value<\/strong><\/p><\/td><\/tr><tr><td><p>Active ingredient<\/p><\/td><td><p>Sirolimus<\/p><\/td><\/tr><tr><td><p>Drug dosage<\/p><\/td><td><p>1,27 \u00b5g\/mm\u00b2<\/p><\/td><\/tr><tr><td><p>Drug carrier<\/p><\/td><td><p>Biocompatible phospholipid<\/p><\/td><\/tr><tr><td><p>Transmission system<\/p><\/td><td><p>Over-the-Wire (OTW)<\/p><\/td><\/tr><tr><td><p>Balloon structure<\/p><\/td><td><p>Semi-compatible<\/p><\/td><\/tr><tr><td><p>Number of balloon floors<\/p><\/td><td><p>3 veya 6<\/p><\/td><\/tr><tr><td><p>Case compatibility<\/p><\/td><td><p>5F\u20138F<\/p><\/td><\/tr><tr><td><p>Guidewire catheter compatibility<\/p><\/td><td><p>6F\u20139F<\/p><\/td><\/tr><tr><td><p>Guide wire options<\/p><\/td><td><p>0,014\u2033, 0,018\u2033 ve 0,035\u2033<\/p><\/td><\/tr><tr><td><p>Balloon diameter options<\/p><\/td><td><p>1,50\u201312,00 mm<\/p><\/td><\/tr><tr><td><p>Balloon length options<\/p><\/td><td><p>20\u2013200 mm<\/p><\/td><\/tr><tr><td><p>Catheter shaft length<\/p><\/td><td><p>45\u2013150 cm<\/p><\/td><\/tr><\/tbody><\/table><h3><strong>Balloon Size Options<\/strong><\/h3><table><tbody><tr><td><p><strong>Guide wire<\/strong><\/p><\/td><td><p><strong>Balloon diameters<\/strong><\/p><\/td><td><p><strong>Balloon lengths<\/strong><\/p><\/td><td><p><strong>Shaft lengths<\/strong><\/p><\/td><\/tr><tr><td><p>0,014\u2033<\/p><\/td><td><p>1,50\u20134,00 mm<\/p><\/td><td><p>20\u2013200 mm<\/p><\/td><td><p>90, 120 ve 150 cm<\/p><\/td><\/tr><tr><td><p>0,018\u2033<\/p><\/td><td><p>2,00\u20137,00 mm<\/p><\/td><td><p>40\u2013200 mm<\/p><\/td><td><p>90, 120 ve 150 cm<\/p><\/td><\/tr><tr><td><p>0,035\u2033<\/p><\/td><td><p>3,00\u201312,00 mm<\/p><\/td><td><p>20\u2013200 mm<\/p><\/td><td><p>45, 80, 90, 130 ve 150 cm<\/p><\/td><\/tr><\/tbody><\/table><blockquote><p>MagicTouch\u2122 PTA is a medical device intended solely for use by healthcare professionals. The manufacturer's documentation, including current usage instructions, should be the basis for indications, contraindications, warnings, product specifications, and application conditions.<\/p><\/blockquote>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>MagicTouch&#x2122; PTA Sirolimus Kapl\u0131 Periferik Anjiyoplasti Balonu MagicTouch&#x2122; PTA, periferik arter hastal\u0131klar\u0131n\u0131n endovask\u00fcler tedavisi i\u00e7in geli\u015ftirilmi\u015f, sirolimus kapl\u0131 bir PTA balon kateteridir. \u00dcr\u00fcn; y\u00fczeyel femoral arter (SFA), popliteal arter, diz alt\u0131 arterleri (BTK) ve iliak arterlerde g\u00f6r\u00fclen de novo lezyonlar\u0131n, stenotik lezyonlar\u0131n ve stent i\u00e7i restenozlar\u0131n perk\u00fctan transl\u00fcminal anjiyoplasti y\u00f6ntemiyle tedavisinde kullan\u0131lmak \u00fczere tasarlanm\u0131\u015ft\u0131r. Sirolimus &hellip; <a href=\"https:\/\/daimmed.com.tr\/en\/magictouch-pta\/\" class=\"more-link\">Continue reading <span class=\"screen-reader-text\">MagicTouch PTA<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-143","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/daimmed.com.tr\/en\/wp-json\/wp\/v2\/pages\/143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/daimmed.com.tr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/daimmed.com.tr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/daimmed.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/daimmed.com.tr\/en\/wp-json\/wp\/v2\/comments?post=143"}],"version-history":[{"count":4,"href":"https:\/\/daimmed.com.tr\/en\/wp-json\/wp\/v2\/pages\/143\/revisions"}],"predecessor-version":[{"id":150,"href":"https:\/\/daimmed.com.tr\/en\/wp-json\/wp\/v2\/pages\/143\/revisions\/150"}],"wp:attachment":[{"href":"https:\/\/daimmed.com.tr\/en\/wp-json\/wp\/v2\/media?parent=143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}